Network - Siemens SCALANCE W770 Series Configuration Manuals

Simatic net industrial wireless lan ieee 802.11n command line interface
Table of Contents

Advertisement

Network protocols
8.5 DHCP server
8.5.3.2

network

Description
With this command you configure the IPv4 address band from which the DHCP client receives
any IPv4 address.
Note
Maximum number of IP addresses
The maximum number of IPv4 addresses that the DHCP server supports is 100. In other words,
a total of 100 IPv4 addresses (dynamic + static).
With the static assignments, you can create a maximum of 20 entries.
Assignment of IP addresses
The requirement for the assignment is that the IPv4 address of the interface is located within
the IPv4 address band. If this is not the case, the interface does not assign any IPv4 addresses
Requirement
You are in the DHCPPOOL configuration mode.
The command prompt is as follows:
cli(config-dhcp-pool-<ID>)#
Syntax
Call up the command with the following parameters:
network <lower-IP> <upper-IP> { <subnet-mask> | / <prefix-length
(1-32)> }
The parameters have the following meaning:
Parameter
lower-IP
upper-IP
subnet-mask
prefix-length
396
Description
Start of the IPv4 address band
End of the IPv4 address band
Subnet mask of the corresponding
subnet
Decimal
representation of the mask as a
number of "1" bits
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Range of values / note
Enter a valid IPv4 address.
Enter a valid IPv4 address.
Enter a valid subnet mask
1 ... 32
Configuration Manual, 09/2017, C79000-G8976-C324-08