Simatic net industrial wireless lan ieee 802.11n command line interface
Table of Contents

Advertisement

Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no snmp community index <CommunityIndex>
The parameter has the following meaning:
Parameter
CommunityIndex
Result
The details of an SNMP community are deleted.
Further notes
You configure the details of an SNMP community with the snmp community index
command.
You show the details of an SNMP community with the show snmp community command.
You show the status information of the SNMP communication with the show snmp command.
8.6.2.8

snmp engineid migrate

Description
With this command, you enable the SNMPv3 user migration.
If the function is enabled, an SNMP engine ID is generated that can be migrated. You can
transfer configured SNMPv3 users to a different device. If you enable this function and load
the configuration of the device on another device, configured SNMPv3 users are retained.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08
Description
Name of the community
Network protocols
8.6 SNMP
Range of values / note
max. 32 characters