Network structures
7.1 WLAN
7.1.5.7

wlan ampdu bytes-limit

Description
With this command, you specify the maximum size of the AMPDU data packet in bytes.
Note
This command is available only in access point mode.
Requirement
● The IEEE 802.11n transmission standard is enabled.
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call up the command with the following parameters:
wlan ampdu bytes-limit <bytes(1024-65535)>
The parameter has the following meaning:
Parameters
bytes
Result
The size for the AMPDU data packets is specified.
Further notes
You display the setting with the show wlan advanced-11n <wlan 0/X> command.
7.1.5.8

wlan ampdu frames-limit

Description
With this command, you specify the number of individual data packets (frames) grouped
together in one AMPDU data packet.
216
Description
Size of the AMPDU data packet in bytes 1024 to 65535 bytes
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08
Range of values / note
Default: 50000 bytes