No Vap Communication With Own-Vap (Access Point) - Siemens SCALANCE W770 Series Configuration Manuals

Simatic net industrial wireless lan ieee 802.11n command line interface
Table of Contents

Advertisement

Security and authentication
11.3 WLAN
11.3.5.9

no vap communication with own-vap (access point)

Description
With this command, you specify that clients logged on to the same SSID of an access point
cannot communicate with each other.
Note
This command is available only in access point mode.
Requirement
You are in the Interface Configuration mode of the VAP interface.
The command prompt is as follows:
cli (config-if-vapX-0-Y)#
Syntax
Call the command without parameter assignment:
no vap communication with own-vap
Result
The communication option on the same SSID of an access point is disabled.
Note
"within own VAP" function disabled
If the "within own VAP" function is disabled the various WLAN clients can no longer see each
other. This means that Address Collision Detection (ACD) also no longer works reliably.
Further notes
You display the settings with the show wlan security <vapX 0/Y> command.
You enable the function with the vap communication with own-vap command.
See also
vap communication with own-vap (access point) (Page 533)
534
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents