Functions specific to SCALANCE
5.1 PLUG
firmware-on-plug
Result
The firmware is stored on the PLUG.
When the device starts up there is a check whether the version on the PLUG is valid and
whether this version matches the version on the device. If this is not the case, the firmware is
installed on the device and it is restarted. This means that automatic firmware updates/
downgrades can be made with the PLUG.
Further notes
You disable this setting with the no firmware-on-plug command.
5.1.3.3

no firmware on plug

Description
With this command, you disable the function. The firmware is removed from the PLUG.
Requirement
● There is a device configuration on the PLUG.
● You are in the Plug Configuration mode.
The command prompt is:
cli(config-plug)#
Syntax
Call the command without parameters:
no firmware-on-plug
Result
The firmware is removed from the PLUG.
5.1.3.4

write

Description
With this command, you format the PLUG and copy the current device configuration to it.