Sntp Unicast-Server - Siemens SCALANCE W770 Series Configuration Manuals

Simatic net industrial wireless lan ieee 802.11n command line interface
Table of Contents

Advertisement

Further notes
You can display the settings of this function and other information with the show sntp
statuscommand.
6.3.3.2

sntp unicast-server

Description
With this command, you configure an SNTP unicast server.
Requirement
● The addressing mode of the SNTP client is configured as "unicast".
● You are in the SNTP Configuration mode.
The command prompt is:
cli(config-sntp)#
Syntax
Call up the command with the following parameters:
sntp unicast-server {ipv4 <ucast_addr> | fqdn-name <FQDN> | ipv6
<ip6_addr>} [port<1025-36564>][poll<seconds(16-16284)>] [secondary]
The parameters have the following meaning:
Parameter
ipv4
ucast_addr
fqdn-name
FQDN
ipv6
ip6_addr
port
poll
seconds
secondary
Result
The SNTP unicast server is configured.
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08
Description
Keyword for an IP address
Value for an IPv4 unicast address
Keyword for a domain name
Domain name (Fully Qualified Domain
Name)
Keyword for an IPv6 address
Value for the IPv6 address of the time
server
UDP port of the time server
Keyword for the time after which the
time of day is requested again
Value for the time in seconds
Keyword to store the second SNTP
server
System time
6.3 SNTP client
Range of values / note
-
Enter a valid IPv4 unicast address.
-
Maximum of 100 characters
-
Enter a valid IPv6 address.
1025 ... 36564
Default: 123
-
16 ... 16284
If you do not specify this parame‐
ter, the first SNTP server is stored.
181

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents