Commands In The Global Configuration Mode; Auto-Save - Siemens SCALANCE W770 Series Configuration Manuals

Simatic net industrial wireless lan ieee 802.11n command line interface
Table of Contents

Advertisement

Configuration
4.4 Configuration Save & Restore
Use the restart command without parameters to restart the system with this configuration.
Further notes
You enable the auto save function or disable the Trial mode with the auto-save command.
You disable the auto save function or enable the Trial mode with the no auto-save command.
4.4.3

Commands in the global configuration mode

This section describes commands that you can call up in the Global configuration mode.
In Privileged EXEC mode, enter the configure terminal command to change to this mode.
Commands relating to other topics that can be called in the Global configuration mode can be
found in the relevant sections.
You exit the Global configuration mode with the end or exit command and are then in the
Privileged EXEC mode again.
4.4.3.1

auto-save

Description
The CLI can save changes to the configuration automatically.
If you first want to test changes made to the configuration so that you can discard them
afterwards if necessary, you can disable the auto save function.
You are then in the Trial mode.
Changes to the configuration that you have not saved, are indicated by an asterisk in front of
the command prompt: *cli(...)#.
You save the changes to the configuration with the write startup-config command.
With the auto-save command, you enable the auto save function.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
auto-save
As default the function is "enabled".
104
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents