Installation; System Configuration Precautions - Omron CS1W-MCH71 Operation Manual

Sysmac cs/cj-series
Hide thumbs Also See for CS1W-MCH71:
Table of Contents

Advertisement

Installation

CPU Bus Unit Allocated
DM Area (DM Parameter
Area)
3-2
Installation
3-2-1

System Configuration Precautions

CJ1W-MCH71
CS1W-MCH71
34
The DM area is allocated 100 words for each unit number starting from the
words D30000.
Unit number
DM area
0
Words 30000-30099
1
Words 30100-30199
2
Words 30200-30299
3
Words 30300-30399
4
Words 30400-30499
5
Words 30500-30599
6
Words 30600-30699
7
Words 30700-30799
• When using the IOWR/IORD instructions for the MC Unit, be sure that a
version 2.0 or later CJ1-H/CJ1M CPU Unit is being used.
• I/O bit numbers of the CPU Bus Unit are allocated based on the setting of
the Unit Number Setting Switch on the front panel of the Unit, not on the
position in which the Unit has been connected.
• MC Units can be connected in either the CPU Rack or in Expansion
Racks. A maximum of 3 MC Units can be connected per Rack. The total
number of MC Units for the CPU Rack and all Expansion Racks is thus 12
MC Units maximum.
• When mounting a relay output unit on the very right of the MC Unit, make
sure to use the surge absorber for the relay output line.
When MECHATROLINK-II devices are connected up to 16 nodes (within
30 m) or 15 nodes (within 50 m), no repeater unit is required. A repeater unit
is required to connect MECHATROLINK-II devices more than the cases
above.
• When using the IOWR/IORD instructions for the MC Unit, be sure that the
CS1@-CPU@@H CPU Unit being used was manufactured on April 18,
2003 (Lot No. 030418) or later.
• The I/O words allocated to a CPU Bus Unit are based on the setting of the
unit number setting switch on the front panel of the Unit, not on the posi-
tion in which the Unit has been mounted.
• The Units can be mounted to the CS1W-BC@@3 or CS1W-BC@@2 CPU
Backplane, or the CS1W-BI@@3 or CS1W-BI@@2 Expansion Backplane.
Unit number
8
9
10
11
12
13
14
15
MC Unit
Make sure to use the surge absorber for the
contact output of this relay output unit.
Section 3-2
DM area
Words 30800-30899
Words 30900-30999
Words 31000-31099
Words 31100-31199
Words 31200-31299
Words 31300-31399
Words 31400-31499
Words 31500-31599