ABS Encoder Origin Setting

8-6
ABS Encoder Origin Setting
8-6-1
Procedure
8-6-2
Setting Up the Related Parameters
Parameters of MC Unit
No.
Name
P1AA01
Physical axis setting
P4AA12
ABS origin offset
P5AA04
Command unit/1
machine rotation
P5AA05
Gear ratio 1
(Motor rotation speed)
P5AA06
Gear ratio 2
(Machine rotation speed)
P5AA07
Axis feed mode
Note
540
Follow the procedure below to set the ABS encoder origin.
Related parameter setting for the MC
Unit and Servo Driver
ABS encoder setup
ABS origin setting for the MC Unit
Follow the above procedure in the following cases:
• When starting up the absolute position detection system for the first time
• When the servomotor was replaced
• When alarm related to the absolute encoder occurred
Value
0: Not used
1~30: MLK devices
31: Reserved
32: Virtual axis
−2147483648~2147483647
1~2147483647
1~10,000,000
1~10,000,000
000000X0h
X (coordinate system management)
0: Limited length
1: Unlimited length
If the parameters [P5AA04], [P5AA05], and [P5AA06] are changed after ABS
origin setting, the alarm [300Dh: ABS encoder error] may occur when the
power is turned ON.
Section 8-6
Remark
Only the MLK slaves can be used as the
absolute value detection system.
Sets the offset amount for the ABS origin
setting.
The present position after ABS origin set-
ting execution will be the value set in this
parameter.
Coordinate system management:
Limited length axis and Unlimited length
axis are treated differently.