Omron CS1W-MCH71 Operation Manual page 206

Sysmac cs/cj-series
Hide thumbs Also See for CS1W-MCH71:
Table of Contents

Advertisement

I/O Variables
Input variable
Size
IW0310
1
IW0311-IW031F
15
IW0320
1
IW0321-IW032F
15
IW0330
1
IW0331-IW033F
15
IW0340-IW0347
8
IW0348-IW035F
24
IW0360-IW036F
16
IW0370-IW043F
208
IW0440-IW045F
32
IW0460-IW047F
32
IW0480-IW049F
32
IW04A0-IW04BF
32
IW04C0-IW04DF
32
IW04E0-IW09FF
1312
IW0A00-IW0A07
8
IW0A08-IW0A0F
8
IW0A10-IW0A3F
56
IW0A40-IW0AFF
192
IW0B00-IW0FFF
1280
Details of Input Variables
Variable Address
bit
R: ■
R/W: ■
IW0000
00
01
02
03
04-15
IW0001
00-15
IW000F
PC21 Bus
Cyclic area
m+20
Unit control data
---
Reserved
n+3
Reserved
---
Reserved
m+21
Reserved
---
Reserved
n+4 − n+11
Motion task 1-8 Control bit
---
Reserved
m+22 − m+37
Motion task 1-8 Control data
---
Reserved
x − x+31
Axis 1-32 Control bit
---
Reserved
d − d+31
Axis1-32 Control Data
---
Axes 1 to 32 internal override
---
Reserved
---
Reserved
---
1.
2.
---
P0004 bit 13 = 1: Motion tasks 1 to 8 are deceleration
banks
---
Reserved
---
Reserved
Custom area
General I/O A-H
The column "Access" indicate the restriction on both read/ write from motion
programs. Of the output variables, the status output area cannot be written
from the user program.
Writing data from motion programs to the input variables allocated to the PLC
bit area enables the MC Unit to control the Unit, tasks, and axes.
Writing data from motion programs to the output variables allocated to the
MECHATROLINK-II output devices and the MC Unit external output terminals
enables the MC Unit to control the signal outputs.
Input variables indicate the data, which will be input to the MC Unit.
Size
CPU
Classification
Unit
Word
1
---
MC Unit External
Input Terminals
15
---
Reserved
Classification
P0004 bit 13 = 0: Motion tasks 1 to 8 are acceleration/
deceleration time banks
P0004 bit 13 = 1: Motion tasks 1 to 8 are acceleration
time banks
Name
External deceleration stop
input
Reserved
External general input 1
External general input 2
Reserved
Reserved
Section 4-6
Access
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Specifications
Reflects the input from the exter-
nal deceleration stop input termi-
nal.
Reserved
Reflects the input from the exter-
nal general input 1 terminal.
Reflects the input from the exter-
nal general input 2 terminal.
Reserved
Reserved
161