Omron CS1W-MCH71 Operation Manual page 608

Sysmac cs/cj-series
Hide thumbs Also See for CS1W-MCH71:
Table of Contents

Advertisement

Coordinate System
Multi-turn data
32767
0
−32768
Machine coordinate
system
0
Using as Unlimited Length
Axis
• If origin setting is executed near the limit of the multi-turn data, a slight
movement will make the axis exceed the limit. Therefore, always initialize
the multi-turn data of the encoder before executing origin setting.
• The operation that the axis is used within the ranges where the multi-turn
data is reset or not reset is shown below:
The range that can be used normally
Within this range, the data from the absolute
encoder is unique. Thus, the present position is
constantly unique.
Same as the case of limited length axis, to execute the axis operation within
the range where the multi-turn data is not reset, use the same setting as the
one for the limited length axis. However, to execute the axis operation exceed-
ing the limit of the multi-turn data, it is required to match the reset timing of the
coordinate system managed in the MC Unit and the reset timing of the
encoder's multi-turn data. To match the timings appropriately, adjust the set-
ting value of the parameter [Pn205: Multi-turn limit setting]. In the case where
the load shaft makes n rotations while the motor makes m rotations, set the
value obtained by subtracting 1 from the denominator of deceleration ratio (m-
1) in Servo Driver parameter Pn205.
Also set the following MC Unit parameters:
P5AA06: n
P5AA05: m
Motor parameter 900C: m-1
If the value other than 65535 is set in the servo parameter [Pn205: Multi-turn
limit setting], the multi-turn data will change as shown below:
Section 9-3
Rotation
amount
Rotation
amount
563