Allocations for the CPU Unit
Custom Bit Area (MC Unit → CPU, 32 words)
Classification
Word
Axis 1 Status bits
x+32
414
Variable
bit
OW0440 00
Axis Alarm
01
Machine Origin
02
Busy
03
In Servo Lock
04
No Origin
05
Axis Operating
06
Positioning Com-
pleted
07
Positioning Com-
pleted (No.2)
08
Error Counter Warn-
ing
09
Axis Machine Lock
Status
10
Counter Latch Com-
pleted
11
MECHATROLINK
Warning
12
Main power ON
(Supported in Unit
Ver. 3.0 or later)
13
Command Disabled/
Enabled
14
Axis Not Used/Used
Name
0: No alarm occurring on axis or MLK slave or
Axis Alarm Reset is ON.
1: Alarm occurring on axis or MLK slave
0: Machine coordinate system FB position is
outside of the origin in-position range
1: Machine coordinate system FB position is
within the origin in-position range.
0: Not executing functions listed below.
1: Executing the functions listed below or
Command is ON JOG, STEP, Origin Search,
Machine Origin Return, Error Counter Reset,
Forced Origin, and ABS Origin Setting
0: In Servo Unlock
1: In Servo Lock
0: Origin on machine coordinate system is
defined
1: Origin on machine coordinate system is not
defined
(Always OFF for virtual axis and ABS encoder
axis whose origin has been already set.)
0: No axis operating command being output
1: Axis operating command being output
0: Outputting positioning command, or axis is
outside of in-position range
1: Not outputting positioning command and
axis is within in-position range.
0: Outputting positioning command, or axis is
outside of No.2 in-position range.
1: Not outputting positioning command, and
axis is within No.2 in-position range.
0: Error amount is within error counter warning
range
1: Error amount exceeded the error counter
warning value
0: Not in Axis machine lock mode
1: In Axis machine lock mode
0: Counter latch not completed
1: Counter latch completed
0: Warning is not detected on MECHA-
TROLINK-II device
1: Warning is detected on MECHATROLINK-II
device
0: Servo Driver main circuit power OFF.
1: Servo Driver main circuit power ON.
0: Not allocated or not implemented
1: Allocated and implemented
(1 for virtual axis unconditionally)
0: Axis is not used
1: Axis is used
(In Manual Mode: JOG, etc. being executed, In
Automatic Mode: Axis declared in the program
that is operating)