Slave Modules
Address
Bit
OW0050
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
OW0051
0
1
2 to 7
8
9
10
11 to 15
Output variables
Symbol
Name
M-SET1
Counter 1
Mode set
N-SET1
Counter 1
Notch point setting
P-SET1
Counter 1
Current value setting
C-ENB1
Counter 1
Count enable
N-ENB1
Counter 1
Notch output enable
P-RES1
Counter 1
Current value reset
N-RES1
Counter 1
Notch output reset
L-RES1
Counter 1
Count value reset
M-SET2
Counter 2
Mode set
N-SET2
Counter 2
Notch point setting
P-SET2
Counter 2
Current value setting
C-ENB2
Counter 2
Count enable
N-ENB2
Counter 2
Notch output enable
P-RES2
Counter 2
Current value reset
N-RES2
Counter 2
Notch output reset
L-RES2
Counter 2
Count value reset
N-ON1
Counter 1
Forced notch output
N-ON2
Counter 2
Forced notch output
Not used
MON1
Monitor 1
MON2
Monitor 2
MON3
Monitor 3
Not used
Description
The counter mode setting signal
ON: Mode setting signal is effective
The notch point setting preset signal
Notch point is set at the rise of the signal (OFF-ON).
The counter's current value preset signal
Current value is set at the rise of the signal (OFF-ON).
Input pulses can be counted when this is ON.
ON: Count enabled
Notch output can be output when this is ON.
ON: Notch output enabled
Counter's current value is reset to "0".
Current value is reset at the rise of the signal (OFF-ON).
Latch status for notch output is reset.
Latch status is reset at the rise of the signal (OFF-ON).
Input status of external latch is reset.
Input status is reset at the rise of the signal (OFF-ON).
The counter mode setting signal
ON: Mode setting signal is effective
The notch point setting preset signal
Notch point is set at the rise of the signal (OFF-ON).
The counter's current value preset signal
Current value is set at the rise of the signal (OFF-ON).
Input pulses can be counted when this is ON.
ON: Count enabled
Notch output can be output when this is ON.
ON: Notch output enabled
Counter's current value is reset to "0".
Current value is reset at the rise of the signal (OFF-ON).
Latch status for notch output is reset.
Latch status is reset at the rise of the signal (OFF-ON).
Input status of external latch is reset.
Input status is reset at the rise of the signal (OFF-ON).
Notch output is forced ON.
ON: Forced output
Notch output is forced ON.
ON: Forced output
Combining the ON/OFF status of Monitor 1 to 3 enables
monitoring of the followings.
• Counter current value
• External latch data
• Status
• Mode settings
• Counter 1, Notch point setting value
• Counter 2, Notch point setting value
• Current set value
Section 10-2