System Parameters
Note
Axis-Position Parameters
Note
No.
Address in MC
Unit
P3AA01
5840h +
(AA * 14h)
Data configuration
31
Travel distance
No.
Address in MC
Unit
P3AA02
5841h +
(AA * 14h)
Data configuration
31
+ direction software limit
Note
No.
Address in MC
Unit
P3AA03
5842h +
(AA * 14h)
Data configuration
31
− direction software limit
Explanation
Sets the S-curve filter time constant at manual feed rate.
For details of Accel/decel patterns, see 6-1-5 Axis Movement Operation (Page
248).
Abbreviation in the No. column:
Abbreviation in the address column: AA = 0 to 31 (axis number − 1)
Name
STEP operation travel distance
Setting range
00000000 to 7FFFFFFF Hex
00
(0 to 2147483647)
Explanation
Sets the travel distance for STEP operation.
Name
Positive direction software limit
Setting range
80000000 to 7FFFFFFF Hex
00
(−2147483648 to 2147483647)
Explanation
Sets the software limit value in the positive direction.
An error will occur when the command value created in every unit scan
exceeds this software limit.
The value has to satisfy the following conditions:
P3AA02 [command unit] = + direction upper limit/minimum setting unit
P3AA03 [command unit] = − direction upper limit/minimum setting unit
P3AA03 < P3AA02
Ex) When positioning X-axis (ball screw) in 0.01 mm unit (P5AA01, P5AA2)
within − 100 to 100 mm, the following values are to be set:
P3AA02 = 100mm/0.01 mm = 10000 [command unit]
P3AA03 = − 100mm/0.01 mm = − 10000 [command unit]
The setting of this parameter is ignored in the following cases:
• When Software limit enabled/disabled (P3AA04) is set to either 0 or 2.
• When an origin has not been defined.
• When Axis feed mode (P5AA07) is set to 0010h (unlimited length).
Name
Negative direction software limit
Setting range
80000000 to 7FFFFFFF Hex
00
(−2147483648 to 2147483647)
AA = 1 to 32 (axis number)
Type
Unit
Data
Command unit
Type
Unit
Data
Command unit
Type
Unit
Data
Command unit
Section 4-2
Immediate
updating
Yes
Initial value
000003E8 (1000)
Immediate
updating
No
Initial value
7FFFFFFF
(2147483647)
Immediate
updating
No
Initial value
80000000
(−2147483648)