Unit Status Bits - Omron CS1W-MCH71 Operation Manual

Sysmac cs/cj-series
Hide thumbs Also See for CS1W-MCH71:
Table of Contents

Advertisement

Interface Specifics
Classification
Status Bits
Busy
In Servo Lock
No Origin
Axis Operating
Positioning Completed
Positioning Completed (No.2)
Axis Machine Lock Status
Command Disabled/Enabled
Axis Not Used/Used
In Manual/Automatic Mode
Effect on Other Functions
System Parameter
Program Example
Present Value Monitor
Condition
Timing Chart
Unit Control Bit:
Present Value Monitor
Select
Unit Status Bit:
Present Value Monitor
Status
Axis Status Data:
Present Value Monitor
7-4-2

Unit Status Bits

Word
Variable
n+15
OW0303
Function
Status Condition
440
Item
Nil
No.
P00004
Unit Function Select
Basic operation:
Command position
(Machine coordinate system)
Command position
(Machine coordinate system)
Command position
(Machine coordinate system)
Bit
00
Unit Ready
This bit indicates the status of operation preparation in the Unit.
Words
bit
n+15
00
No effect
No effect
No effect
No effect
No effect
No effect
No effect
When OFF: [Present Value Monitor] = 0
When ON: No effect
No effect
No effect
Name
Determining the unit for the feedback speed 2
T1
Name
Name
Unit Ready
0: The Unit is not ready to accept commands.
1: The Unit is ready to accept commands.
Section 7-4
Effects
Purpose
n+0.12 to 15
Present Value Monitor Select
Error
Error
Error
I/O
Input
Specifications

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Cj1w-mch71