Omron CS1W-MCH71 Operation Manual page 379

Sysmac cs/cj-series
Hide thumbs Also See for CS1W-MCH71:
Table of Contents

Advertisement

Command Details
Operand
Operand
Setting range
Speed command
See note 1.
value
Speed change rate
0 to 60000ms
Note
Description
334
Axis Name: J01 to J32
Decimal
Bit
Yes
No
No
No
(1) With Rated % specification (P00004 bit2 = 0):
This is the % specification for the motor rated rotations in the unit of
0.01%. The setting range is − 500000 to 500000.
If the value I0000 is set, it is interpreted as 100% of the rated rotations.
The maximum speed in actual operations is limited by the maximum ro-
tation speed of the motor.
With r/min specification (P00004 bit2 = 1):
This is the specification of rotations (r/min) in the unit of 0.01 r/min. Set-
ting range is − 10000000 to 10000000.
If the value 300000 is set, it is interpreted as 3000r/min.
The maximum speed in actual operations is limited by the maximum ro-
tation speed of the motor.
(2) Word data is extended to long word data with a sign in the MC Unit.
(3) With Rated % specification (P00004 bit2 = 0)
The minimum command unit is 0.01%.
The actual value = (Decimal immediate value or Variable of real number
type) × 10
2
)
Figures below the decimal point are to be omitted.
In case of r/min specification (P00004 bit2 = 1)
The minimum command unit is 0.01%.
The actual value = ((Decimal immediate value or Variable of real number
type) × 10
2
)
Figures below the decimal point are to be omitted.
(4) There is no influence. ABL specification is always used.
• The speed command is output to the specified axis.
• The speed command unit is specified in the parameter [P00004.bit02:
Unit function select, Speed command value]
[P00004.bit02] = 0 [0.01% of the rated speed]
[P00004.bit02] = 1 [0.01r/min]
• If Speed change rate is set to 0, the specified speed is output instantly. (If
the mode is switched from other mode to the speed control mode, this
value can be used as the output speed default value.)
• The Speed change rate is enabled for all the specified axes.
• SPEED command execution will be completed when the speed command
for all the specified axes reaches Speed command value.
• The SPEEDR command is processed as follows:
(1) The speed command is decelerated for all specified axes according to
the speed change rate and the speed command is output as 0.
(2) The system waits until the feedback speed equals the speed in P3AA09
or lower.
(3) The mode is switched to positioning control mode and the system waits
for the completion of positioning.
Variable specification
Word
Long
Real
word
number
Yes (See
Yes
Yes (See
note 2.)
note 3.)
Yes (See
Yes
Yes
note 2.)
Section 6-3
INC/ ABL
influ-
Indirect
ence
specifi-
cation
Yes
No (See
note 4.)
Yes
No

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Cj1w-mch71

Table of Contents