Omron CS1W-MCH71 Operation Manual page 660

Sysmac cs/cj-series
Hide thumbs Also See for CS1W-MCH71:
Table of Contents

Advertisement

Slave Modules
Address
Bit
Symbol
OW0031
0
ARST2
Word 2
1
CAN2
2
MONSEL2
3
PSET2
4 to 7
PRM20 to
PRM23
8
MOV2
9
JOG2
10
ZRN2
11
REV2
12
Not used
13
COFF2
14
BFREE2
15
OUT2
OW0032
OW0033
OW0034
OW0035
Parameter
Parameter No. setting
No.
PRMn3
PRMn2
00
OFF
OFF
01
OFF
OFF
02
OFF
OFF
Name
Alarm reset
Cancel
Monitor selector
Parameter set/Monitor
selector
Parameter No. selector Parameter No. is selected using this signal.
Positioning
JOG operation
Zero point return
JOG/Zero point return
direction
Output current OFF
Electromagnetic brake
release
General-purpose out-
put
Word 1 data register
Word 2 data register
Meaning of the parameters No. select and setting value of the pulse
output module
PRMn1 PRMn0
OFF
OFF
Reserved for system
OFF
ON
Output mode
ON
OFF
In JOG operation
• JOG speed
• JOG accel/decel time
Description
This is the alarm-reset command.
Alarm is reset at the rise of the signal (OFF-ON).
This signal cancels axis movement.
Axis movement is canceled at the rise of the signal (OFF-
ON).
This signal switches the monitor mode.
OFF: Current position monitor, ON: Parameter monitor
This is the signal that sets or monitors parameters.
This signal starts positioning operation.
Operation is started at the rise of the signal (OFF-ON).
This signal controls JOG operation.
ON: Run
OFF: Stop
This signal starts the zero point return operation.
Operation is started at the rise of the signal (OFF-ON).
This signal determines the starting direction for JOG opera-
tion and zero point return operation.
OFF: Forward
ON: Reverse
This signal controls the status of the output current OFF
terminal.
OFF: Output current ON, ON: Output current OFF
This signal controls the status of the electromagnetic brake
release output terminal.
OFF: Electromagnetic brake is used.
ON: Electromagnetic brake is released.
This signal controls the status of the general-purpose out-
put terminal.
OFF: General-purpose output is OFF.
ON: General-purpose output is ON.
Appropriate setting enables setting of the following values
of Word 1.
• Target position setting
• Parameter settings
Appropriate setting enables setting of the following values
of Word 2.
• Target position setting
• Parameter settings
Name
Setting range (units)
0: CW, CCW pulses
1: + signed pulses
JOG speed:
1 to 50000 (10 pps)
Accel/decel time
50 to 5000 (100 ms)
Section 10-2
Initial
setting
0
Speed:
500
Time:
100
615