Omron CS1W-MCH71 Operation Manual page 697

Sysmac cs/cj-series
Hide thumbs Also See for CS1W-MCH71:
Table of Contents

Advertisement

Axis-related Alarm Codes
Name
Error log
Error
Detail
code
Axis classifi-
037Ah
3015h
cation error
-
0399h
No origin
3016h
proximity sig-
nal
Origin proxim-
3017h
ity and over
travel simulta-
neously ON
No origin sig-
3018h
nal
652
Alarm
code
code
3015h
Attempted to execute a command that can-
not be executed as an axis. (The command
that requires an external signal (MOVEI,
etc.) was executed on the virtual axis, or
the winding axis of MOVETRAV is not set
as an unlimited length axis, etc.)
Correct the applicable parameters or pro-
gram.
3016h
During an origin search in the limit reversal
mode, there was no deceleration limit
switch in between over travel of both direc-
tions.
Provide the origin proximity limit switch, or
check if the limit switches themselves or
wiring is normal.
3017h
During an origin search, the deceleration
limit switch and the over travel in direction
of the search were turned ON simulta-
neously.
Check if the origin proximity signal, or over
travel signals for both directions are wired
correctly.
3018h
During an origin search, the over travel sig-
nal turned ON while waiting for the origin
signal (while waiting for the rise of phase-Z
after the fall (ON to OFF) of the origin prox-
imity limit switch).
Check if the settings of the axis parameter
[P4AA06: Origin determine signal] and the
servo parameter [Pn511: Input signal
select 5] are correct (if the applicable signal
is enabled).
If the settings are correct, check the follow-
ings:
• Problem on Phase-Z of the encoder
• Breakage of encoder cable
• Too small distance between the origin
proximity limit switch and the limit switch
These causes are to be removed.
Cause and remedy
Section 11-6
Timing
Rank
Reset
When a
Decelera-
Enabled
com-
tion stop
mand is
exe-
cuted.
In origin
Immediate
Enabled
search
stop
In origin
Immediate
Enabled
search
stop
In origin
Immediate
Enabled
search
stop