Main Parameter Settings when Connecting W-series Servo Driver with Built-in MECHATROLINK-II Communications
Required Parameter Settings
The following servo parameters are used to control the MC Unit. Make sure that they are set correctly and do
not change them.
List
Parameter No.
Pn800.0
Communications control, MECHATROLINK-II communications check mask
Pn800.1
Communications control, warning check mask
Pn801.0
Software limit function
Pn801.2
Software limit Check Using Reference
Pn824
Option monitor 1 selection
Pn825
Option monitor 2 selection
Pn008.2
Function selection application switches 8, warning detection selection
Pn20E
Electronic gear ratio G1 (numerator)
Pn210
Electronic gear ratio G2 (denominator)
Individual Descriptions
Pn800.0 Communications Control, MECHATROLINK Communications Check Mask
Parameter
Parameter name
No.
Pn800.0
Communications control
MECHATROLINK-II communica-
tions check mask
Make sure that MECHATROLINK communications errors, such as A.E60 (communications error) and A.E50
(WDT error (synchronization error)), can be detected. The MC Unit uses them when controlling communica-
tions.
Use the default setting of 0 (communications error (A.E60) and WDT error (A.E50)) for Pn800.0.
Pn800.1 Communications Control Warning Check Mask
Parameter
Parameter name
No.
Pn800.1
Communications control, warning
check mask
Make sure that MECHATROLINK communications warnings, such as A.94@ (data setting alarm) and A.95@
(command alarm), are not ignored. The MC Unit uses them when controlling communications.
Set Pn800.1 to the default setting of 4 (ignore communications alarm (A.96@) only or to 0 (detect A.94@,
A.95@, and A.96@).
Pn801.0 Software Limits
Parameter
Parameter name
No.
Pn801.0
Software limits
Leave the software limit function set on the default setting of 3.
668
Parameter
Unit
Fixed
setting
---
0
0: Detects communica-
tions error (A.E60) and
WDT error (A.E50)
Unit
Fixed
setting
---
4 or 0
4: Ignore communications
warnings (A.96@)
0: Detect A.94@, A.95@,
and A.96@.
Unit
Setting
range
---
0 to 3
0: Enables software limit1:
Enables forward soft-
ware limit
2: Enables reserve soft-
ware limit
3: Disables both software
limits
Appendix B
Settings
Default
settings
0
Settings
Default
settings
4
Settings
Default
settings
3
Required
settings
0
Required
settings
0
Required
settings
3