Config...\Survey Settings...
Field
Option
Next step
IF files for raw
observations
are not to be config-
ured
are to be configured
Description
•
For static operations with long baselines and over
long time <Log Rate: 15.0s> or <Log Rate:
30.0s>.
•
For reference stations for post-processed and
real-time kinematic rovers, <Log Rate:> at the
reference should be the same rate as at the rover.
•
For initialisation while static and occupying distinct
points in kinematic chains <Log Rate: > between
0.1s and 2.0s.
THEN
CONT (F1) closes the screen and returns to the screen from where
CONFIGURE Logging of Raw Obs was accessed.
FILES (F6). Refer to paragraph "CONFIGURE Raw Observation
Files".
GPS1200+