Config...\Interfaces... - General
Description of fields
Field
Option
<Info to Log:> Choicelist
<Polarity:>
Negative Edge or
Positive Edge
<Bias Intern:> User or Factory
<Intern Bias:> User input
<Extern Bias:> User input
CONT (F1)
NPORT (F4)
Description
Activates the detection and logging of events being
sent to the event ports.
The polarity according to the device in use.
Accepts personal or default settings as calibration
values for the particular receiver.
Available for <Bias Intern: User>. Sets the particular
calibration value in ns for the receiver.
Sets a calibration value in ns according to the
external event device and cable being used.
GPS1200+
To accept changes and return to the screen
from where this screen was accessed.
To configure the port and the device through
which the notification message shall be trans-
mitted. Refer to "22.16 Remote".