Config...\Interfaces... - Controlling Devices
Step
Description
<IP Address:> The IP address of the selected <Server:> as config-
ured in CONFIGURE Server to Connect.
For <User: Server>: Output of the IP address associated with the
NET port as configured in CONFIGURE Set NET Parameter.
<Host:> The host name of the selected <Server:> as configured in
CONFIGURE Server to Connect. For RX1250 receivers only.
<TCP/IP Port:> The TCP/IP port number of the selected <Server:>
as configured in CONFIGURE Server to Connect.
<Auto CONEC:> Available for <User: Client>.
For <R-Time Mode: Rover> in CONFIGURE Real-Time Mode
Allows for automatic connection between the rover and the Internet
when a point is occupied during a survey. Ending the point occupa-
tion also ends the Internet connection.
For <R-Time Mode: Reference> in CONFIGURE Real-Time Mode
Automatically tries to establish a connection to the Internet for data
streaming. After the streaming was interrupted for some reason,
SHIFT CONEC (F4) in the Survey screen.
5.
PAGE (F6) to access CONFIGURE Set NET Port, Ranges page
6.
CONFIGURE Set NET Port, Ranges page
For <User: Server> in CONFIGURE Set NET Port, General page,
the fields are input fields. The fields <Range X From:> and <Range
X To:> can be used to prevent a user with an IP address outside the
defined ranges from accessing the receiver.
GPS1200+
Refer to
chapter
20.5