Manage...\Jobs
Step
Description
9.
MANAGE New Job, Avge page
In order to check measurements, the same point can be measured
more than once. If activated, an average or an absolute difference is
calculated.
<Averaging Mode:> Defines the averaging principles for multiple
measured points. <Averaging Mode: Average> computes the
average for the position and the height. Points exceeding the defined
limits are marked with in MANAGE Edit Point, Mean page. <Aver-
aging Mode: Absolute Diffs> computes the absolute differences
between two points selected from a list of measured points which are
all stored with the same point ID. The selection determines the avail-
ability of the subsequent fields for setting the acceptable averaging
limits or absolute differences.
For <Averaging Mode: Average>:
<Method:> The method used for computing the average.
<Method: Weighted> calculates a weighted average while
<Method: No Weighting> is calculating an arithmetic average.
<Points to Use:> The type of points which will be taken into
account for averaging.
<Avge Limit Pos:> and <Avge Limit Ht:> The acceptable differ-
ence for the position and height components.
GPS1200+
Refer to
chapter
9.3.4