22.16
Description
Config...\Interfaces... - General
Remote
The remote interface allows:
•
the receiver to be controlled using a device other than the RX1200, e.g. a PC. Outside
World Interface or Leica Binary 2 commands can be used to control the receiver through
the remote port. Documentation for OWI and LB2 is available on request from the Leica
Geosystems representative.
•
a message log to be requested from a remote client via an OWI message. A message log
contains a history of warning messages and message lines. It is not possible to view a
message log in the RX1200.
•
the downloading of data directly from the receiver's memory device to LGO through a
serial port on the PC. The RX1200 does not need to be removed from the receiver.
The settings on this screen define the port and the device to be used for the remote control.
A port configured as a remote port can be used to output event input, meteo or tilt notification
messages.
Except for the GRX1200+ Series the OWI commands listed below are protected by a licence
key. Refer to "30 Tools...\Licence Keys" for information on how to type in the licence key. The
corresponding LB2 commands are also protected. If these OWI commands have been acti-
vated by a licence key is indicated in STATUS System Information, Instrument page.
•
AHT
•
DPM
•
ANT
•
GGA
•
CNF
•
GLL
•
DCF
•
GNS
•
DCT
•
LLK
•
LLQ
•
GGK
•
GGK(PT)
•
GGQ
•
POS
GPS1200+
•
RMC
•
POQ
•
RTK
•
SCC
•
TPV
•
USR
•
POB
•
POE
571