Description
Averaging
Manage...\Data

Mean Page

In order to check measurements, the same point can be measured more than once.
These measured points are assigned the class MEAS. The various measured coordinate
triplets for one point can be recorded using the same point ID. If the averaging mode is acti-
vated, an average is calculated when more than one measured coordinate triplet is available
for the same point ID.
The averaged point is given the class AVGE. It is checked if the deviations of each single
point are within the limits configured in MANAGE New Job, Avge page or in MANAGE Edit
Job: Job Name, Avge page.
After averaging, the Mean page becomes available in MANAGE Edit Point: Point ID and
accessible from the Survey application program SURVEY Survey: Job Name, Survey
page.
Available functionality on the Mean page depends on the selected averaging mode.
Averaging Mode
The averaging mode defines the checks which are performed when more than one set of
measured coordinates are recorded for the same point. The selected averaging mode also
affects the behaviour of the instrument when editing a point and calculating averages.
Defining the averaging mode and configuring the limits
The averaging mode and the limits are configured in MANAGE New Job, Avge page or in
MANAGE Edit Job: Job Name, Avge page. Refer to "8.3 Creating a New Job". Refer to "8.4
Editing a Job".