Figure 14-47. Database Operations Page; Database Operations Page - Comtech EF Data CDM-570 Installation And Operation Manual

70/140 mhz satellite modem, l-band satellite modem, reduced chassis depth l-band satellite modem
Hide thumbs Also See for CDM-570:
Table of Contents

Advertisement

CDM-570/570L Satellite Modem with Optional IP Module
Ethernet IP Module - CLI and Telnet Operation

14.2.11.4 Database Operations Page

Activate the Database Operations page from Operations and Maintenance page. Use this page to
view, save, or erase an existing user configuration of the IP Module. An IP Module uses these
types of configuration files to initialize itself on power-up.
The User Configuration File is used to overwrite the values defined in the Factory Configuration
file. Allows full customization of an IP Module without erasing the factory-defined parameters
set.
The User Configuration File can also be retrieved or overwritten via FTP by
specifying the filename 'param1'.
The Database Operations page contains the following options/fields:
Selection
Restore Factory Default
Load Parameters from
permanent storage
Automatically Save
PARAM after CONFIG
change

Figure 14-47. Database Operations page

Entry
Description
R
Restores the IP Module settings to "safe" values as defined by the factory.
Overwrites the current configuration of the IP Module with the configuration
P
last saved to permanent storage. This performs an "undo" type operation if
the user puts the IP Module into an undesirable state.
Enable to automatically save any configuration changes, including changes
A
made from the front panel.
14–66
Revision 12
MN/CDM570L.IOM