CDM-570/570L Satellite Modem with Optional IP Module
Appendix K
(ODU SELECT) INFO: Misc
Cold Start: Off
Auto Fault Recovery: On
This read-only screen shows the current state of the Cold Start and Auto Fault Recovery
functions as ON or OFF.
K.3.3.1.1.1.1.3
ODU SELECT: Monitor
ODU MONITOR: Tx Rx Misc
Pwr-Supp1 Pwr-Supp2 (◄ ►)
For access to real-time, read-only information displays on the ODU currently in operation: Use the
◄ ► arrow keys to select Tx, Rx, Misc, Pwr-Supp1, or Pwr-Supp2, and then press ENTER.
The screen shots that follow depict sample configurations – the actual values
and settings will vary and they are dependant on the ODU configuration in use.
Typical for all nested screens, press ENTER or CLEAR to return to the ODU
SELECT: Monitor menu.
(ODU SELECT) ODU MONITOR: Tx
TX: SynTune=04.8 Pwr=040
IFLO = 10.7
This read-only screen shows the Tx Synthesizer and IFLO tuning voltages, the RF Output
Power in dBm and the Transmitter temperature.
(ODU SELECT) ODU MONITOR: Rx
RX: Synth Tune = 03.1
IFLO = 10.9
This read-only screen shows the Rx Synthesizer and IFLO tuning voltages and the Receiver
temperature.
(ODU SELECT) ODU MONITOR: Misc
MISC: Ref Tune = 03.0
LNA=000.0mA FAN=568.0mA
This read-only screen shows the Internal Reference Oscillator tuning voltages, the LNA
Current in milliamps and the Fan Current in milliamps.
(ODU SELECT) ODU MONITOR: Pwr-Supp1
PS: 24V=23.8
12V=13.0
This read-only screen shows a monitor for four of the six internal power supplies.
(ODU SELECT) ODU MONITOR: Pwr-Supp2
Temp = 27 oC
Temp = 28 oC
20V=22.6
10V=10.1
K–13