CDM-570/570L Satellite Modem with Optional IP Module
Appendix D
Command
Parameter
(Instruction
Type
Code and
Qualifier)
Number of Unread
N/A
3 bytes
stored Statistics
Outdoor Unit
ODU=
1 byte,
Comms Enable
value of 0 or 1
ReCenter Buffer
RCB=
None
Retrieve next 5
N/A
75 bytes
unread Stored
Events
Arguments for
Command or
Response to
Query
Query only.
Unit returns the number of stored statistics that remain Unread, in the form xxx.
Note: This means unread over the remote control.
Example: NUS=247
Command or Query – CDM-570 Only.
Enables or disables communications, via the FSK link, with a Comtech EF Data
transceiver (ODU), where:
0=Disabled
1=Enabled
Example: ODU=0 (selects Disabled)
Command only.
Forces the software to recenter the receive Plesiochronous/Doppler buffer.
Note: This command takes no arguments.
Example: RCB=
Query only.
Unit returns the oldest 5 Stored Events which have not yet been read over the
remote control. Reply format: {CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}Sub-
body{CR}Sub-body, where Sub-body= ABCddmmyyhhmmss,
A being the fault/clear indicator.
F=Fault
C=Clear
I=Info
B being the fault type where:
1=Unit
2=Rx Traffic
3=Tx Traffic
4=ODU
5= Power on/off, or log cleared
C is Fault Code numbers, as in FLT? or Info Code, which is:
0=Power Off
1=Power On
2=Log Cleared
3=Global Config Change
4=Redundancy Config Change
If there are less than 5 events to be retrieved, the remaining positions are padded
with zeros. If there are no new events, the response is RNE*.
Description of Arguments
D–26
Revision 12
MN/CDM570L.IOM
Query
Response to
(Instruction Code
Command
and Qualifier)
N/A
NUS?
NUS=xxx
(see Description of
Arguments)
ODU=
ODU?
ODU=x
ODU?
(see Description of
ODU*
Arguments)
ODU#
RCB=
N/A
N/A
RCB?
RCB*
RCB#
RNE?
RNE={CR}ABCddm
N/A
myyhhmmss{CR}A
BCddmmyyhhmms
s{CR}ABCddmmyy
hhmmss{CR}ABCd
dmmyyhhmmss
{CR}ABCddmmyyh
hmmss
(see description for
details of
arguments)
Response to
Query