Registering A Cimom Server - Brocade Communications Systems StoreFabric SN6500B User Manual

Brocade network advisor san user manual v12.0.0 (53-1002696-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

2. To register a CIMOM server, refer to
3. To edit a CIMOM server, refer to
4. To import CIMOM servers, refer to
5. To export CIMOM servers, refer to
6. To edit CIMOM server credentials for one or more CIMOM servers, refer to
7.
8. To delete CIMOM servers, refer to
9. Click OK to close Port Commissioning Setup dialog box.

Registering a CIMOM server

Before you can decommission or recommission an F-Port, you must register the CIMOM servers
within the fabric affected by the action.
1. Select Configure > Port Commissioning > Setup.
2. Enter the IP address (IPv4 or Ipv6 format) or host name of the CIMOM server in the Network
3. (Optional) Enter a description of the CIMOM server in the Description field.
4. Enter the CIMOM port number for the CIMOM server in the CIMOM Port field.
Brocade Network Advisor SAN User Manual
53-1002696-01
Description — User-defined description of the system.
CIMOM Port — The CIMOM port number of the system.
Namespace — The namespace of the CIM_FCPort.
User ID — The user identifier for the system.
Status — The system connectivity status. Updates when you test the reachability of the
CIMOM server and when you contact the CIMOM server to respond to the F-Port
decommission or recommission request. Valid status options include:
OK — CIMOM server contact successful with current credentials.
Not Contacted Yet — CIMOM servers configured, connectivity not tested yet.
Credentials Updated — Credentials changed, connectivity not tested yet.
Credentials Failed — CIMOM server contact failed with current credentials.
Not Reachable — CIMOM server not reachable.
Wrong Namespace— CIMOM server namespace is incorrect.
Last Contacted — The last time you contacted the system. Updates when you test the
reachability of the CIMOM server and when you contact the CIMOM server to respond to
the F-Port decommission or recommission request.
server credentials"
on page 372.
To validate CIMOM server credentials, refer to
page 372.
The Port Commissioning Setup dialog box displays
Address field.
The description cannot be over 1024 characters.
The default port number is 5989.
Port commissioning overview
"Registering a CIMOM server"
"Editing CIMOM server credentials"
"Importing CIMOM servers and credentials"
"Exporting CIMOM servers and credentials"
"Testing CIMOM server credentials"
"Deleting CIMOM server credentials"
(Figure
on page 369.
on page 370.
on page 371.
on page 371.
"Changing CIMOM
on
on page 373.
135).
12
369