12
Ports
2. Review the port optics information.
366
Combined Status — Displays the current status of the port.
NOTE
Requires a 16 Gbps capable port running Fabric OS 7.0 or later.
NOTE
The device must have a Fabric Watch license and threshold monitoring configured for the
port. For more information, refer to the Fabric Watch Administrator's Guide.
If the port is online and port monitoring is active, displays the current status of the port
based on these five parameters: Transceiver Temp (C), Rx Power, Tx Power, Transceiver
Current (mAmps), and Voltage (mVolts).
If the port is offline, displays the current status of the port based on these two parameters:
Transceiver Temp (C) and Voltage (mVolts).
Status icons:
Warning icon — One of the five parameters exceeds the threshold of that parameter.
The corresponding parameter field displays with a yellow background.
No icon — No parameters exceed the threshold of that parameter.
Unknown icon — The port is not a 16 Gbps capable port or the device is running
Fabric OS 6.4.X or earlier.
Error icon — Unable to retrieve status of the supported port.
Slot/Port # — The slot and port number of the selected fabric. The port number includes
the type of port (FC, TE, GE, or XGE).
FC Address — The Fibre Channel address of the port.
TX Power — The power transmitted to the SFP in dBm and uWatts.
NOTE
The uWatts display requires devices with Fabric OS 6.1.0 and later. Devices running
Fabric OS 6.0.0 and earlier only display dBm.
RX Power — The power received from the port in dBm and uWatts.
NOTE
The uWatts display requires devices with Fabric OS 6.1.0 and later. Devices running
Fabric OS 6.0.0 and earlier only display dBm.
Transceiver Temp (C) — The temperature of the SFP transceiver.
Voltage (mVolts) — The voltage across the port in mVolts.
Transceiver Current (mAmps) — The laser bias current value in mAmps.
Powered on Years (Hours) — The powered on time in years and hours for 16 Gbps capable
ports. Empty for unsupported ports.
NOTE
Requires a 16 Gbps capable port running Fabric OS 7.0 or later.
FC Speed (GB/s) (Fabric OS 7.0 or later) — The FC port speed; for example, 4 Gbps.