28
FC troubleshooting
888
TABLE 79
Status Detail messages
Operation/Test
Disable the diagnostic mode on
source or destination D ports
Lost connectivity to switch while
test is in progress
Diagnostic port test timed out
The Management application
waits 30 minutes to complete
the test. If not completed, the
test times out.
Electrical Loopback Test
Optical Loopback Test
Link Traffic Test
Distance between ports
Reverse Optical Loopback Test
Roundtrip link latency
Buffers required
Link Traffic Test Configuration
used
Possible message
Failed to enable the port slot_number/port_number of the switch
switch_IP_address.
Reason: CAL_error_message
Disabled diagnostic mode on port slot_number/port_number of the
switch switch_IP_address.
Failed to disable diagnostic mode on port slot_number/port_number of
the switch switch_IP_address.
Reason: CAL_error_message
Connection failed to the switch during the operation.
Diagnostic port test time-out. You may need to change the port
configuration before retrying.
Successfully completed Electrical Loopback Test on port
slot_number/port_number of the switch switch_IP_address.
Electrical Loopback Test failed on port slot_number/port_number of the
switch switch_IP_address. Reason: CAL_error_message
Electrical Loopback Test skipped on port slot_number/port_number of
the switch switch_IP_address.
Reason: CAL_error_message
Successfully completed Optical Loopback Test.
Optical Loopback Test failed
Optical Loopback Test skipped.
Reason: CAL_error_message
Successfully completed Link Traffic Test.
Link Traffic Test failed.
Approximate distance between the ports is numerical_value meters.
Successfully completed Reverse Optical Loopback Test.
Reverse Optical Loopback Test failed.
Roundtrip link latency: numerical_value nano-seconds.
Buffers required: numerical_value
No. of test frames: numerical_value Million
Duration of test (HH:MM): hours:minutes
Test frame size: numerical_value Bytes
Payload Pattern: pattern_name or frame_data
FEC (enabled/active): Yes/No
CR (enabled/active): Yes/No
Start time: day month date hour:minute:seconds year
End time: day month date hour:minute:seconds year
NOTE: If you do not set a payload pattern, results do not show payload
pattern.
Brocade Network Advisor SAN User Manual
53-1002696-01

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Brocade network advisor 12.0.0

Table of Contents