Brocade Communications Systems StoreFabric SN6500B Manual

Brocade virtual connect enterprise manager server guide v12.0.0 (53-1002808-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:

Advertisement

53-1002808-01
17 December 2012
Virtual Connect Enterprise
Manager Server Guide
Supporting Brocade Network Advisor 12.0.0
®

Advertisement

Table of Contents
loading

Summary of Contents for Brocade Communications Systems StoreFabric SN6500B

  • Page 1 53-1002808-01 ® 17 December 2012 Virtual Connect Enterprise Manager Server Guide Supporting Brocade Network Advisor 12.0.0...
  • Page 2: Document History

    Copyright © 2011 - 2012, Brocade Communications Systems, Incorporated. Brocade, the B-wing symbol, BigIron, DCX, Fabric OS, FastIron, IronPoint, IronShield, IronView, IronWare, JetCore, NetIron, SecureIron, ServerIron, StorageX, and TurboIron are registered trademarks, and DCFM, Extraordinary Networks, and SAN Health are trademarks of Brocade Communications Systems, Inc., in the United States and/or in other countries.
  • Page 3 Virtual Connect Enterprise Manager server discovery The Management application enables you to discover Virtual Connect Enterprise Manager (VCEM) servers. NOTE You can discover up to 2 VCEM servers. Discovering a VCEM server To discover a VCEM server, complete the following steps. 1.
  • Page 4 3. Enter the IPv4 IP address or fully qualified domain name in the Network Address field. 4. Enter the VCEM server SOAP API port number(default is 50001) in the Port field. 5. Enter the VCEM server username in the User ID field. 6.
  • Page 5 Removing a VCEM server from active discovery If you decide you no longer want the Management application to discover and monitor a specific VCEM server, you can delete it from active discovery. To delete a VCEM server from active discovery, complete the following steps. 1.
  • Page 6 Viewing the VCEM server discovery state The Management application enables you to view device discovery status through the Discover VCEM Servers dialog box. To view the discovery status of a device, complete the following steps. 1. Select Discover > VCEM Servers. The Discover VCEM Servers dialog box displays.
  • Page 7: Right-Click Menus

    Virtual Connect module product icons The following table lists the manageable Virtual Connect (VC) module product icons that display on the topology. Icon Description Icon Description VC module Multi-fabric VC module Right-click menus Menu item Description Product Only available when VC is missing from one fabric, but present in another fabric. Select to shift the view from the current VC (which is missing) to the VC present in the other fabric.
  • Page 8: Properties Tab

    TABLE 1 Properties tab Field Description IO Bay Discovery Status The discovery status of the VCEM server of this module. Last Discovery The last time data collection was performed for this VC module on the VCEM server. TABLE 2 Port tab Field Description Fabric...
  • Page 9: Vcem Integration Support In Smi-A

    VCEM integration support in SMI-A NOTE Discovery of TopologyView and SANActiveConnections will be incomplete for VC modules connected to the end devices due to lack off support in the HP SOAP API. HP SAN Network Advisor supports virtual connect discovery for the HP VC 8Gb 24-port FC module and VC 8Gb 20-port FC module through the HP Virtual Connect Enterprise Manager (VCEM) server.
  • Page 10 10 of 10 Virtual Connect Enterprise Manager Server Guide Publication Number: 53-1002808-01...

Table of Contents