Chapter 14 Fault CodesMS300
ID
Display on LCD Keypad
Fault Name
Fault Descriptions
EEPROM read error
31
Internal EEPROM cannot be read
(cF2)
Action and Reset
Action Condition
Firmware internal detection
Action Time
cF2 acts immediately when the drive detects the fault
Fault Treatment Parameter
N/A
Reset Method
Manual reset
Reset Condition
Immediately reset
Record
Yes
Cause
Corrective Actions
Press "RESET" key or reset the parameter to the default setting, if cF2 still
Internal EEPROM cannot be read
exists, return to the factory for repair.
Cycle the power, if cF2 error still exists, return to the factory for repair.