Chapter 12 Descriptions of Parameter SettingsMS300
02-22
Desired Frequency Reached 1
Settings
02-23
The Width of the Desired Frequency Reached 1
Settings
02-24
Desired Frequency Reached 2
Settings
02-25
The Width of the Desired Frequency Reached 2
Settings
 Once the output speed (frequency) reaches the desired speed (frequency), if the corresponding
multi-function output terminal is set to 3 or 4 (Pr.02-13, Pr.02-16, and Pr.02-17), this multi-
function output terminal is "closed".
02-34
Output Frequency Setting for Multi-function Output Terminal
Settings
Multi-Function Output Terminal (Function 42): Brake Frequency Check
02-58
Point
Settings
 Use Pr.02-34 with Pr.02-58 for the crane function and select the crane function MO #42 to set
the multi-function outputs Pr.02-13, Pr.02-16, and Pr.02-17.
 When the output frequency (H) is lower than the setting for Pr.02-58, multi-function output
terminal setting 42 stops after the command breaks off.
 Pr.02-58 must be lower than Pr.02-34 when using MO = 42.
 When using Pr.02-34 with close-loop control, Pr.02-58 is the reference motor speed (encoder
feedback).
0.00–599.00 Hz
0.00–599.00 Hz
0.00–599.00 Hz
0.00–599.00 Hz
0.00–599.00 Hz
0.00–599.00 Hz
314
Default: 60.00 / 50.00
Default: 2.00
Default: 60.00 / 50.00
Default: 2.00
Default: 0.00
Default: 0.00