Chapter 14 Fault CodesMS300
ID
Display on LCD Keypad
106
Action Condition
Action Time
Fault Treatment Parameter
Reset Method
Reset Condition
Record
Cause
Incorrect setting of CANopen
station address
Fault Name
CANopen station
address error
(CAdE)
Action and Reset
Software detection
Immediately act
N/A
Manual reset (Pr.00-02 = 7)
N/A
Yes
1. Disable CANopen (Pr.09-36 = 0)
2. Reset CANopen (Pr.00-02 = 7)
3. Reset CANopen station address (Pr.09-36)
614
Fault Descriptions
CANopen station address error (only supports 1–127)
Corrective Actions