Chapter 14 Fault CodesMS300
ID
Display on LCD Keypad
Fault Name
Fault Descriptions
U-phase error
33
U-phase current detection error when power is ON
(cd1)
Action and Reset
Action Condition
Hardware detection
Action Time
cd1 acts immediately when the drive detects the fault
Fault Treatment Parameter
N/A
Reset Method
Power-off
Reset Condition
N/A
Record
Yes
Cause
Corrective Actions
Cycle the power.
Hardware failure
If cd1 still exists, return to the factory for repair.