Delta MS300 Series User Manual page 488

Standard compact drive
Hide thumbs Also See for MS300 Series:
Table of Contents

Advertisement

ID No.
Display on LCD Keypad
8
Action Condition
Action Time
Warning Setting Parameter
Reset Method
Reset Condition
Record
Cause
Add new parameters to the new
firmware version.
Malfunction caused by
interference
Warning Name
Save error 2
(SE2)
Action and Reset
"SE2" warning occurs when writing the parameters incorrectly at the time you
copy parameters to the drive. For example, you copy the new firmware version
with added parameters to the drive with old firmware version.
N/A
N/A
Manual reset
Immediately reset
N/A
SE2: In this stage, the copied data has been transmitted to the Slave.
The Slave compares and processes the copied data, and then saves the data
to the Data ROM. During the process, the data error (should be attribution
error) may occur, or the data cannot be saved to EEPROM. At this time, the
warning occurs.
It is suggested to check the status of Data ROM and remove the error causes
first.
If you cannot clear the error, please contact Delta.
Verify the wiring and grounding of the main circuit and control circuit for
effective anti-interference performance.
479
Chapter 13 Warning CodesMS300
Description
Keypad COPY error 2: parameter writing error
Corrective Actions

Hide quick links: