Chapter 12 Descriptions of Parameter SettingsMS300
Pr.
Operation command source
00-21
(AUTO, REMOTE)
Motor 1 maximum operation frequency
01-00
Acceleration time 1
01-12
Deceleration time 1
01-13
Analog input selection (AVI)
03-00
Analog input curve selection
03-50
AVI voltage lowest point
03-63
AVI voltage mid-point
03-65
AVI proportional mid-point
03-66
Terminal selection of PID feedback
08-00
Proportional gain (P)
08-01
Integral time (I)
08-02
PID mode selection
08-20
Enable PID to change the operation
08-21
direction
PID target value source
08-65
PID target value setting
08-66
 Setting 12: Tension PID + master / auxiliary frequency
The following table lists the relevant tension PID + master / auxiliary frequency setting
application parameters.
Pr.
Master frequency command source
00-20
(AUTO, REMOTE)
Operation command source
00-21
(AUTO, REMOTE)
Motor 1 maximum operation frequency
01-00
Acceleration time 1
01-12
Deceleration time 1
01-13
Auxiliary frequency source
00-35
Analog input selection (AVI)
03-00
Analog input selection (ACI)
03-01
Reverse setting when analog signal input
03-10
is negative frequency
Analog input gain (ACI)
03-12
ACI terminal input selection
03-29
Parameter Name
Parameter Name
448
Settings
1 (External terminals)
Default setting
3 (sec.)
3 (sec.)
5 (PID feedback signal)
1: Three-point curve of AVI
0.00
9.99
100%
1: Negative PID feedback: by analog input
(Pr.03-00, Pr.03-01)
10
1
1: Parallel connection
0: Operation direction cannot be changed
1: Pr.08-66 setting
50%
Settings
9 (PID controller)
1 (External terminals)
Default setting
3 (sec.)
3 (sec.)
3: Analog input
5 (PID feedback signal)
12: Auxiliary frequency input
0: Negative frequency input is not allowed.
The digital keypad or external terminal
controls the forward and reverse
direction.
100.0%
1: 0–10 V