Chapter 16 PLC Function ApplicationsMS300
16-5-4 PLC Communication address
Device
X
Y
T
M
M
C
D
D
Command codes that can be used
Function Code
H1
H2
H3
H5
H6
HF
H10
NOTE:
When PLC functions have been activated, the MS300 can match the PLC and drive parameters; this method
uses different addresses for drives (default station number is 1, PLC sets station number as 2).
Range
00–17 (Octal)
00–17 (Octal)
00–79
000–799
1000–1279
0–39
00–199
1000–1219
Function Descriptions
Coil status read
Input status read
Read single unit of data
Force single coil status change
Write single unit of data
Force multiple coil status change
Write multiple units of data
Type
bit
bit
bit/word
bit
bit
bit/word
word
word
692
Address (Hex)
0400–040FF
0500–050F
0600–064F
0800–0B1F
0BE8–0CFF
0E00–0E27
1000–10C7
13E8–14C3
Table 16-14
Function target
Y, M, T, C
X, Y, M, T, C
T, C, D
Y, M, T, C
T, C, D
Y, M, T, C
T, C, D
Table 16-15