16-6-5 Detailed explanation of drive special application commands
API
RPR
139
P
bit device
X
Y
M
K
S1
S2
Notes on operand usage: none
S
: Parameter address of data to be read. S
1
stored.
API
WPRA
140
P
bit device
X
Y
M
S1
S2
Notes on operand usage: none
Word device
H
KnX KnY KnM
S1
S2
Word device
K
H
KnX KnY KnM
S
: Data to write to specified page. S
1
written.
When the data in the MS300 drive's parameter H01.00 is read and written to
D0, data from H01.01 is read and written to D1.
When M0 = ON, the content of D10 is written to the MS300 drive Pr.04.00
(first speed of multiple speed levels).
When M1017 = ON, the parameter has been written successfully.
The MS300's WPRA command does not support writing to the 20XX address,
but the RPR command supports reading of 21XX, 22XX, 61XX.
Chapter 16 PLC Function ApplicationsMS300
Read servo parameter
16-bit command (5 STEP)
T
C
D
RPR
32-bit command
Flag signal: none
: Register where data that is read is
2
Write servo parameter
16-bit command (5 STEP)
T
C
D
WPRA
32-bit command
Flag signal: M1016 parameter read/write error,
M1017 parameter written successfully.
: Parameter address of data to be
2
757
Continuous
RPRP
execution type
execution type
Continuous
execution
WPRP
type
Pulse
Pulse
execution
type