Heavy load (Pr.00-16=1)
Space Vector Modulation Mode (Pr.11-41 = 2)
The rated output current (%) of SVPWM in heavy load for different carrier frequencies:
Carrier Freq.
(kHz)
Ambient Temp.
(Ta), 100% Load
50°C
40°C
35°C
Two-phase Modulation Mode (Pr.11-41 = 0)
The rated output current (%) of DPWM in heavy load for different carrier frequencies:
Carrier Freq.
(kHz)
Ambient Temp.
(Ta), 100% Load
50°C
40°C
35°C
2
3
4
5
100
100
100
88
100
100
100
100
100
100
100
100
2
3
4
5
100
100
100
100
100
100
100
100
100
100
100
100
Figure 9-9
6
7
8
9
80
72
65
59
95
86
78
71
100
93
84.5
77
Figure 9-7
6
7
8
9
100
93
86
80
100
100
100
95
100
100
100
100
193
Chapter 9 SpecificationsMS300
10
11
12
13
53
48
44
40
65
59
54
50
71
64.5
59
55
10
11
12
13
74
69
65
61
89
83
78
73
96.5
90
84.5
79
14
15
36
33
46
42
51
46.5
Table 9-17
14
15
57
53
69
65
75
71
Table 9-18