Chapter 11 Summary of Parameter SettingsMS300
Pr.
Explanation
Maximum Torque
11-27
Command
11-28
Torque Offset Source
11-29
Torque Offset Setting
11-30
High Torque Offset
11-31
Middle Torque Offset
11-32
Low Torque Offset
11-33
Torque Command Source
11-34
Torque Command
Torque Command Filter
11-35
Time
11-36
Speed Limit Selection
Forward Speed Limit
11-37
(Torque Mode)
Reverse Speed Limit
11-38
(Torque Mode)
11-41
PWM Mode Selection
11-42
System Control Flag
Settings
0–500%
0: Disable
1: Analog signal input
2: RS-485 communication (Pr.11-29)
3: Controlled through external terminals
(Pr.11-30–11-32)
-100.0–100.0%
-100.0–100.0%
-100.0–100.0%
-100.0–100.0%
0: Digital keypad
1: RS-485 communication (Pr.11-34)
2: Analog signal input (Pr.03-00)
3: CANopen
5: Communication Card
-100.0–100.0%
0.000–1.000 sec.
0: Set by Pr.11-37 (forward speed limit) and Pr.11-38
(reverse speed limit)
1: Set by Pr.00-20 (Master frequency command (AUTO,
REMOTE) source) and Pr.11-37, Pr.11-38
2: Set by Pr.00-20 (master frequency command (AUTO,
REMOTE) source)
0–120%
0–120%
0: Two-phase modulation mode
2: Space vector modulation mode
0000–FFFFh
254
Default
100
0
0.0
30.0
20.0
10.0
0
0.0
0.000
0
10
10
2
0000