Delta MS300 Series User Manual page 718

Standard compact drive
Hide thumbs Also See for MS300 Series:
Table of Contents

Advertisement

API
FEND
06
bit device
X
Y
M K
Notes on operand usage:
No operand
A contact-driven command is not needed.
Word device
H
KnX KnY KnM
This command indicates the end of the main program. It is the same as
the END command when the PLC executes this command.
The CALL command program must be written after the FEND command,
and the SRET command is added to the end of the subprogram.
When using the FEND command, an END command is also needed.
However, the END command must be placed at the end, after the main
program and subprogram.
Chapter 16 PLC Function ApplicationsMS300
End of a main program
16-bit command (1 STEP)
Continuous
T
C
D
FEND
execution type
32-bit command
Flag signal: none
709