Delta MS300 Series User Manual page 468

Standard compact drive
Hide thumbs Also See for MS300 Series:
Table of Contents

Advertisement

 Basic motor parameters adjustment
Parameter reset:
1.
Reset Pr.00-02 = 9 (50 Hz) or 10 (60 Hz) to the default value.
Select PM motor type:
2.
Pr.05-33 = 1 (SPM) or 2 (IPM)
Motor nameplate parameter setting:
3.
Parameter
Pr.01-01
Pr.01-02
Pr.05-34
Pr.05-35
Pr.05-36
Pr.05-37
PM parameter auto-tuning:
4.
Set Pr.05-00 = 5 (rolling auto-tuning for PM, with no load) or 13 (static auto-tuning for PM)
and press RUN key to finish motor auto-tuning, then you will get the following parameters:
Parameter
Pr.05-39
Pr.05-40
Pr.05-41
Pr.05-43
If an auto-tuning error (AUE) occurs, refer to Chapter 14 "Fault Codes and Descriptions" for
further treatment.
AUE Error (code)
AUE (40)
AUE1 (142)
AUE2 (143)
Set control mode
5.
Control mode for the drive: Pr. 00-10 = 0: Speed mode
Control mode for the motor: Pr. 00-11 = 2: PM SVC mode
Re-power on after power off.
6.
Measure the initial magnetic pole angle of PM
7.
Set Pr.10-53 PM initial rotor position detection method
0: Disabled
1: Using I/F current command (Pr.10-31) to attract the rotor to zero degrees
2: High frequency injection
3: Pulse injection
(For IPM, the setting value is suggested to be 2; for SPM, the setting value is suggested to
be 3. You can choose the setting 1 if the result is not good of setting as 2 or 3.)
Rated frequency (Hz)
Rated voltage (V
)
AC
Rated current (A)
Rated power (kW)
Rated rotor speed (rpm)
Number of poles for the motor (poles)
Stator resistance for a permanent magnet motor (Ω)
Permanent magnet motor Ld (mH)
Permanent magnet motor Lq (mH)
Ke parameter of a permanent magnet motor (V
(When Pr.05-00 = 5, the Ke parameter is measured based on the actual motor
rotation.)
(When Pr.05-00 = 13, the Ke parameter is automatically calculated based on
the motor power, current and rotor speed.)
Auto-tuning error
Auto-tuning error 1 (No feedback current error)
Auto-tuning error 2 (Motor phase loss error)
459
Chapter 12 Description of Parameter SettingsMS300
Description
Description
phase , rms
Description
/ krpm)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents