Chapter 10 Digital KeypadMS300
C. Application Macro Selection Page
Go to Parameter Group 13 to set the application macro functions. The application macro function is
enabled when Pr.13-00 ≠ 0.
Once enabled, the Application Marco Selection page displays "APP". If Pr.13-00 = 0, the APP page
does not display.
When Pr.13-00 ≠ 0, you enter into the APP page. After you press ENTER, the screen displays a
corresponding short name according to Pr.13-00 setting values. Follow the process below to set the
industry-specific application macro parameters.
Set Pr.13-00
(Select your application)
Example:
When Pr.13-00 = 2, you enter into the APP page. After you press ENTER, the screen displays
"CoPr" and the compressor application macro parameters are enabled. Then, press ENTER again
to check the industry-specific parameter sets. Press Up and Down keys to select the parameter to
set. Finally, press ENTER to set the parameter values. For other industry application, follow the
same process.
Set Pr.13-00 = 1 to enable the user-defined applications. The "USEr" appears in the APP page after
pressing ENTER.
(If Pr.13-00 = 1 and you do not set any parameters for Pr.13-01–Pr.13-50, you cannot enter the sub-
layer of the USEr page.)
After selecting your application,
press MODE to return to the
APP page. Then, press ENTER
to enter into the industry-specific
short name page. Pressing
ENTER again displays the
application macro parameters
for the industry.
200
Use Up and Down key
to select the application
parameters, and then
press ENTER to check
and set the setting.