Chapter 7 Optional AccessoriesMS300
The table below shows the THDi specification when using Delta's drives to work with AC/DC reactors.
Drive Spec.
Reactor
No AC/DC
Spec.
Reactor
5th
73.3%
7th
52.74%
11th
7.28%
13th
0.4%
THDi
91%
The THDi specification listed here assumes that there is 0.8% resistance (mains electricity) before the reactors
and may be slightly different from the actual THDi, depending on the installation and environmental conditions
NOTE
(wires, motors).
Models without Built-in DC Reactors
3% Input AC
5% Input AC
Reactor
Reactor
38.5%
30.8%
15.3%
9.4%
7.1%
6.13%
3.75%
3.15%
43.6%
34.33%
Models with Built-in DC Reactors
4% DC
No AC Input
Reactor
Reactor
25.5%
31.16%
18.6%
23.18%
7.14%
8.6%
0.48%
7.9%
38.2%
42.28%
64
3% Input AC
5% Input AC
Reactor
Reactor
27.01%
25.5%
9.54%
8.75%
4.5%
4.2%
0.22%
0.17%
30.5%
28.4%
Table 7-22