Settings
There is a group of block transfer parameters available in the AC motor drive (Pr.09-11–Pr.09-
26). Using communication code 03H, you can store the parameters (Pr.09-11–Pr.09-26) that you
want to read.
For example: according to the Address List (as shown in the table below), Pr.01-42 is shown as
012A. Set Pr.09-11 to 012Ah (the minimum voltage of Pr.01-42 M2 is 2.0 V), and use Pr.09-11
(communication address 090B) to read the communication parameter, the read value is 2.0.
AC motor drive
parameters
Mind if the block transfer parameters are read only. If the data is written to read-only parameters
from the upper unit, a communication error may occur.
09-30
Communication Decoding Method
Settings
EtherCAT card only supports decoding method 2 (60xx).
Decoding Method
Digital Keypad Digital keypad controls the drive action regardless of decoding method 1 or 2.
External
Terminal
Source of
RS-485
Operation
CANopen
Control
Communication
NOTE: Refer to Section 15-4 CANopen Supported Index for the definition of 6000H.
0–65535
GGnnH
0: Decoding method 1 (20xx)
1: Decoding method 2 (60xx)
External terminal controls the drive action regardless of decoding method 1 or
2.
RS-485 controls the drive referring to index 2000h–20FFh
Refer to index: 2020-01h–2020-FFh
Refer to address: 2000h–20FFh
Card
PLC
PLC command controls the drive action regardless of decoding method 1 or 2.
Chapter 12 Descriptions of Parameter SettingsMS300
GG is the parameter group, nn is the parameter number;
for example, the address of Pr.04-10 is 040AH.
Method 1
417
Default: 0
Default: 1
Method 2
Refer to index:2060-01h–2060-FFh
Refer to address: 6000h–60FFh