Delta MS300 Series User Manual page 196

Standard compact drive
Hide thumbs Also See for MS300 Series:
Table of Contents

Advertisement

9-5 General Specifications
Control Method V/F, SVC, FOC Sensorless
Applicable Motor IM (Induction Motor), Simple PM motor control (IPM and SPM)
Starting Torque*
Speed Control
Range*
Max. Output
Frequency
Overload Capacity
Control
Characteristics
Frequency Setting
Signal
Main Functions
Application Macro
Motor Protection Over-current, Over-voltage, Over-heating, Phase loss.
Protection
Characteristics
Stall Prevention
Communication
Cards
Accessory
External DC
Power Supply
Certifications*
Safety Function*
NOTE:
Control accuracy may vary depending on the environment, application conditions or different motors. For more information,
1.
contact Delta or your local distributors.
For information on Certifications and Declaration of Conformity (DoC), visit
2.
Delta | Download Center (deltaww.com)
150% / 3 Hz
1
100% / (motor rated frequency/20)
200% / 0.5 Hz
1: 50 (V/F, SVC control for IM, heavy duty, rated)
1: 20 (SVC control for PM, heavy duty, rated)
1
1: 100 (FOC control for IM, heavy duty, rated)
0.00–599.00 Hz
Normal duty:
120% of rated current can endure for 1 minute during every 5 minutes
150% of rated current can endure for 3 seconds during every 30 seconds.
Heavy duty:
150% of rated current can endure for 1 minute during every 5 minutes
200% of rated current can endure for 3 seconds during every 30 seconds
0–10 V / -10–10 V
4–20 mA / 0–10 V
1 channel pulse input (33 kHz), 1 channel pulse output (33 kHz)
Multiple motor switching (a maximum of four independent motor parameter
settings), Fast start-up, Deceleration Energy Back (DEB) function, Wobble
frequency function, Fast deceleration function, Master and Auxiliary
frequency source selectable, Restart after momentary power loss, Speed
tracking, Over-torque detection, 16-step speed (including the master speed),
Accel./decel. time switch, S-curve accel./decel., three-wire operation control,
JOG frequency, Frequency upper/lower limit settings, DC brake at start-up
and stop, PID control, Built-in PLC (2000 steps), and Simple positioning
function.
Built-in application parameter groups (selected by industry) and user-defined
application parameter groups.
Stall prevention during acceleration, deceleration and running (independent
settings).
DeviceNet, EtherNet/IP, PROFIBUS DP, Modbus TCP, CANopen, EtherCAT
EMM-BPS01 (24 V power backup supply card)
2
UL, CE, RCM, TÜV (SIL 2), RoHS, REACH
2
TUV (SIL2)
(V/F, SVC control for IM, heavy duty,
rated)
(SVC control for PM, heavy duty, rated)
(FOC control for IM, heavy duty, rated)
187
Chapter 9 SpecificationsMS300
Table 9-10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents