Chapter 16 PLC Function ApplicationsMS300
API
EDIV
123
D
bit device
X
Y
M
S1
S2
D
Notes on operand usage:
Refer to the function specifications table for each device in series
for the scope of device usage.
P
Word device
K
H
KnX KnY KnM
S
: dividend. S
: divisor. D: quotient.
1
2
Divides the content of the register designated by S
register designated by S
D; division is performed entirely using binary floating point numbers.
If the source operand S
converts that constant into a binary floating point number for use in division.
When X1 = ON, divides the binary floating point number (D1, D0) by the binary
floating point number (D11, D10), and stores the quotient in the register
designated by (D21, D20).
When X2 = ON, divides the binary floating point number (D1, D0) by K1,234
(which is automatically converted to a binary floating point number), and stores
the results in (D11, D10).
X2
DEDIV
Divide binary floating point numbers
16-bit command
T
C
D
32-bit command (13 STEP)
DEDIV
Flag signal: none
and stores the quotient in the register designated by
2
or S
designates a constant K or H, the command
1
2
D0
K1234
D10
730
Continuous
DEDIVP
execution type
execution type
by the content of the
1
Pulse