Delta MS300 Series User Manual page 52

Standard compact drive
Hide thumbs Also See for MS300 Series:
Table of Contents

Advertisement

Recommended models or dimensions for crimping terminals
Wire Gauge
Manufacturer
0.2 mm
2
PHOENIX CONTACT
(24 AWG)
0.34 mm
2
PHOENIX CONTACT
(22 AWG)
0.5 mm
2
PHOENIX CONTACT
(20 AWG)
Recommended specifications and models for crimping tool:
CRIMPFOX 10S - 1212045, Manufacturer: PHOENIX CONTACT
DNT13-0101, Manufacturer: DINKLE
Terminals
Terminal Function
Digital control signal common
+24 V
(Source)
MI1
Multi-function input 1–7
MI7
Figure 6-8
Model Name
A (MAX)
AI 0,25- 8 YE
12.5
AI 0,34- 8 TQ
12.5
AI 0,5 - 8 WH
14
+24 V
± 10 % 100 mA
DC
When used in parallel, if the +24V terminal is used with a
feedback sensor, unequal current may occur, and there will
be a risk of failure.
Refer to Pr.02-01–02-07 to program the multi-function
inputs MI1–MI7.
Source Mode
ON: activation current is 3.3 mA and the voltage is 11 V
OFF: cut-off voltage ≤ 5 V
Sink Mode
ON: activation current is 3.3 mA and the voltage is 13 V
OFF: cut-off voltage ≥ 19 V
When Pr.02-00 = 0, MI1 and MI2 can be programmed.
When Pr.02-00 ≠ 0, the functions of MI1 and MI2 act
according to Pr.02-00 setting.
When Pr.02-07 = 0, MI7 is pulse input terminal.
MI7 uses pulse input, and the maximum input
frequency = 33 kHz. You can use it as frequency
command source or connect it to the encoder for motor
closed-loop control.
MI7 motor closed-loop control only supports VFPG
control mode.
43
Chapter 6 Control TerminalsMS300
B (MAX)
D (MAX)
8
2.6
8
3.3
8
3.5
Description
DC
DC
Unit: mm
W (MAX)
1.1
1.3
1.4
Table 6-2
DC
DC